Interventional echocardiographers receive higher radiation doses than interventional cardiologists

In 60 structural heart procedures, the interventional echocardiographer's median dose per case was 10.6 µSv against the interventional cardiologist's 2.1 µSv, and a second study found the highest exposure at the waist and lower body.

In structural heart procedures such as mitral valve repair (TEER) and left atrial appendage closure (LAAO), the interventional echocardiographer guides the case with a transesophageal probe, standing near the patient and the x-ray source, where scatter comes from. Two studies have measured what that position receives.

Higher doses than the cardiologist at the table

McNamara and colleagues put real-time dosimeters on interventional echocardiographers, interventional cardiologists and sonographers through 30 consecutive LAAO and 30 consecutive TEER procedures at one center.1 Across all 60 cases, the median dose per case was 10.6 µSv for the echocardiographer and 2.1 µSv for the interventional cardiologist.

  • LAAO: 10.6 µSv against 3.5 µSv, 3.0 times higher.
  • TEER: 10.5 µSv against 0.9 µSv, 11.7 times higher.

The echocardiographer received more than 20 µSv in 30% of LAAO cases and 27% of TEER cases. The authors chose that mark because it is roughly ten times the mean dose previously reported for interventional cardiologists across a range of procedures. Sonographers received low doses throughout.1

The waist and lower body

Kataoka and colleagues modeled where scatter lands on an echocardiographer’s body and checked the model against measurements in 79 procedures (44 TEER, 35 transcatheter aortic valve replacements).2 The highest exposure fell on the right half of the body, especially the waist and lower body, from radiation scattered at the bottom edge of the patient bed. Waist exposure was higher in TEER than in valve replacement. The authors conclude that interventional echocardiographers, especially young women, should be taught about this exposure, and they note that the ovary is in the exposed area.

Shielding the echo position

In a phantom study of EggNest® Complete, scatter at the echo or EP implanter position was 96% lower than with standard cath lab shielding, averaged over five C-arm angulations. The study was sponsored by Egg Medical, and its authors note the results need confirming in clinical studies.3 See the study on the Evidence page.

Sources

  1. McNamara DA, Chopra R, Decker JM, et al. Comparison of radiation exposure among interventional echocardiographers, interventional cardiologists, and sonographers during percutaneous structural heart interventions. JAMA Netw Open. 2022;5(7):e2220597. doi:10.1001/jamanetworkopen.2022.20597
  2. Kataoka A, Takata T, Yanagawa A, et al. Body surface radiation exposure in interventional echocardiographers during structural heart disease procedures. JACC Asia. 2023;3(2):301-309. doi:10.1016/j.jacasi.2022.12.008
  3. Riley RF, Kamen J, Tao A, Gomez-Cardona D. Comparative effectiveness of the EggNest Complete shielding system to standard shielding in the cath lab. Am Heart J Plus. 2025;54:100543. Site reference 14. doi:10.1016/j.ahjo.2025.100543

More from the EggBlog

Other articles.

  • 14 April 2025

    Torrance Memorial installs EggNest Protect in its cath lab

    Torrance Memorial Medical Center installed EggNest Protect in its cardiac catheterization lab, paid for by a charitable donation, and says it is the first hospital in California to do so.

    Read the article
  • 14 September 2023

    Patient BMI and physician radiation dose in coronary angiography

    In 1,119 coronary angiograms, physicians received 7.0 times the radiation dose when the patient's BMI was 40 or more than when it was under 25.

    Read the article
  • 18 February 2022

    Anesthesiologists in the cath lab are exposed to more radiation than in the operating room

    A study of anesthesia fellows recorded under 10 mrem a month in the operating rooms and 20 to 180 mrem a month in the cath lab, and a review explains why the position is hard to shield.

    Read the article

See every article

Want to see what EggNest can do for your lab?